T8DCS UV-Vis - Ace MART
Edit Template
, ,

T8DCS UV-Vis

T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm.

It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field.

The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution.

The use of a photomultiplier tube as detector delivers exceptional sensitivity.

The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.

 

Product Name T8DCS UV-Vis

 

Catalogue Download

 

 

Product Description T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm.

It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field.

The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution.

The use of a photomultiplier tube as detector delivers exceptional sensitivity.

The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.

Features Photomultiplier tube detection provides exceptional sensitivity

Wavelength accuracy +0.3nm (Automatic Wavelength Correction)

User selectable spectral bandwidth between 0.1-5nm

User friendly design allows easy light source replacement and routine maintenance

Sample compartment design enables use of a wide range of optional accessories

UV-Win software offers many operational and data processing capabilities and is supplied as standard with the T8DCS

Principle The spectral bandwidth is one of the main factors that affect the quantitative analysis error of UV/Vis Spectrophotometer. After studying the influences of spectral bandwidth on the analysis error, T. Owen pointed out that the spectral bandwidth of the UV/Visible Spectrophotometer is very important. When the spectral bandwidth (SBW) / natural bandwidth (NBW) ≤ 0.1 (natural bandwidth, which is half width of the sample absorp

tion band), the instrument can meet the requirements of 99% sample analysis , and analysis accuracy can reach up to 99.9%. Below is an application example in drug inspection industry:

As we can see, the peak value is the highest when the spectral bandwidth is 0.4nm, indicating that the best spectral bandwidth is 0.4nm. In addition, the most suitable spectral bandwidth for drugs, such as Penicillin Potassium and Cytochrome C solution, can be found through experiments. Thus reduce the measurement steps, reduce testing costs, and save measurement time. The T8DCS features an advanced continuous variable bandwidth and excellent performance. It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientific research field.

 

Application Biotech & life science clinical analysis, disease control analysis, micro-sample testing in the field of life, human biochemical index analysis, metabolite analysis, test the micro samples of life science and provide DNA/Protein detector to measure the DNA/Protein concentration etc.

Environmental monitoring & control Monitoring of water quality, atmospheric pollution, rainfall and soil contamination.

Food & Beverage production and quality control Analysis of additives preservatives and flavors, fat contents, enzyme, glucose, flavoring, minerals, vitamins, etc.

Agricultural monitoring Can be applied in various agriculture, such as pesticide detection, crop analysis, animal medicine analysis, fertilizer inspection, soil analysis, animal food stocks inspection etc.

Geology & Metallurgy: Determination of metallic elements and inorganic salt in minerals.

Clinical & forensic analysis Measuring the change in absorbance of turbid biological samples can be challenging as the inherent background absorbance of the sample may be over 4 Abs

Education in universities and colleges Determination of complex composition, Obtaining kinetics curves, acid-base dissociation constant, photometric titration, etc.

 

 

 

Reviews

There are no reviews yet.

Be the first to review “T8DCS UV-Vis”

Your email address will not be published. Required fields are marked *

Achieve Your Research Goals with Our Technologies and Proven Research Strategies.

Making accessible basic and high research technologies to developing countries at affordable prices.

Community Service

AceMART Projects

What we do

How we do

Who Benefits

Company Profile

About AceMART

Brands

Careers

Awards

Experts engagement

Code Values

News letter

Ace Customers stories

Sustainability plan

Legal Center

Terms and conditions

Website disclaimer

Trademarks

Third-party privacy

Cookie notice

Registration & License

Popular links

UV-Vis Spectroscopy

Phase identification

Particle size Analyzer

ROS Analyzer

X-ray diffraction (XRD)

X-ray fluorescence (XRF)

Support & Suppport

Product support

Events and training

Knowledge center

Software downloads

Products Manuals

Ace MART © Copyright 2024 Developed By Ai Tech
Scroll to Top